Theory
Humid air is treated as an ideal-gas mixture of dry air and water vapour. The relative humidity is the ratio of the partial pressure of the vapour to its saturation pressure at the gas temperature. The saturation pressure follows the formula of Annex B of ISO 9613-1 (1993); the mole fraction of water vapour is the partial pressure divided by the absolute static pressure of the gas, which is the operating pressure of the Material step (the outlets' absolute pressure when the flow is solved).
The mixture's molar mass and its heat-capacity polynomial are the mole-fraction-weighted values of dry air and water vapour, from the same species data as dry air and exhaust gas. The viscosity remains the Sutherland law of dry air, as for exhaust gas.
The formula of the standard is written for atmospheric conditions. Compared with the saturation pressure of IAPWS (2012) it gives at 20 °C, at 85 °C, at 100 °C and at 150 °C. A warning appears above 100 °C; above 200 °C only the mole fraction can be entered. Liquid water is not modelled: a humidity whose vapour pressure would reach the static pressure is refused.
Equations
| where | meaning | unit |
|---|---|---|
| Saturation vapour pressure of water at | Pa | |
| Reference pressure, 101 325 | Pa | |
| Triple-point isotherm temperature, 273.16 | K | |
| Gas temperature | K |
| where | meaning | unit |
|---|---|---|
| Mole fraction of water vapour | - | |
| Relative humidity | % | |
| Absolute static pressure of the gas (operating pressure) | Pa |
| where | meaning | unit |
|---|---|---|
| Molar mass of the humid gas | kg/kmol | |
| Molar mass of dry air | kg/kmol | |
| Molar mass of water | kg/kmol |
Default and rule
- Default
- 0 %
- Rule
0 % (dry air).
- Source
Saturation pressure: ISO 9613-1 (1993), Annex B. Deviation figures: computed against the saturation-pressure equation of IAPWS (2012), whose own verification values the program reproduces to all printed digits.
Valid range 0 - 100 %; refused when the vapour pressure would exceed the static pressure
Condensation
is refused: the water would condense, and liquid water is not modelled.
Hot gas
Above 100 °C the saturation formula is used outside the range it was written for; the deviation from IAPWS-IF97 grows from 0.6 % at 100 °C to 1.7 % at 150 °C.
Mole fraction
Above 200 °C, or when the water content is known as a mole fraction, enter Water-vapour mole fraction instead.