SpectraSim Documentation
Parameter · 07 Run Settings

Compressor duct length

machine.duct_length_m Unit: m Step 07 · Run Settings

The equivalent length of the compressor duct: measure it from the compressor to the throttle or the stack. Without it neither the Helmholtz frequency nor B can be computed.

Last updated

Theory

The model and the duct of the compressor that feeds it form a compression system: the duct (area AcA_c, equivalent length LcL_c) holds the moving mass of gas, the volume behind it the compressible gas. Like a Helmholtz resonator, the system oscillates at ωH\omega_H. The card is shown only when its toggle on the Run Settings step is on (it is meant for a model fed by a compressor or turbocharger). Greitzer (1976) showed that one non-dimensional number, BB, decides whether a disturbance at the stall line of the compressor grows into surge (an oscillation of the whole system) or settles into rotating stall; a larger BB moves the system towards surge. The paper's own cases, from B=0.45B = 0.45 to B=5B = 5, show that the value at which this happens depends on the compressor: there is no universal limit, so the card shows BB as an indicator, without a pass or fail. The model was derived for axial compressors; Fink, Cumpsty & Greitzer (1992) extended it to a centrifugal compressor with a free spool, and Haeckel et al. (2023) use it for the surge limit of a turbocharger compressor, so the card applies to both.

The plenum volume is the fluid volume of the model (the closed skin of the exported geometry, packing regions included) plus the extra volume entered here. The speed of sound is that of the gas at the operating state. None of these numbers is used by a solver; they can be changed before or after a run.

Equations

ωH=c AcVp Lc,fH=ωH2π,B=U2 ωH Lc\omega_H = c\,\sqrt{\frac{A_c}{V_p\,L_c}}, \qquad f_H = \frac{\omega_H}{2\pi}, \qquad B = \frac{U}{2\,\omega_H\,L_c}
(1)
wheremeaningunit
ωH\omega_HHelmholtz angular frequency of the compression systemrad/s
ccSpeed of sound at the operating statem/s
AcA_cCompressor duct aream²
VpV_pPlenum volume: model fluid volume + extra volumem³
LcL_cEquivalent compressor duct lengthm
UUImpeller tip speed, πDn/60\pi D n/60m/s

Default and rule

Default
0.25 m (Haeckel et al. 2023)
Rule

0.25 m: the length from the environment to the compressor inlet of the short-intake rig ("System 2") of Haeckel et al. (2023) (Table 1; their long intake was 7.5 m). Replace it with the equivalent length of your compressor duct.

Source

Greitzer (1976), eqs. 9 and 15.

Valid range > 0

Indicator

The card reports B; the paper gives no universal limit for it.

References 3

  1. Fink, D. A.; Cumpsty, N. A.; Greitzer, E. M. (1992). Surge dynamics in a free-spool centrifugal compressor system. Journal of Turbomachinery, 114(2), 321-332. DOI 10.1115/1.2929146
  2. Greitzer, E. M. (1976). Surge and rotating stall in axial flow compressors, Part I: Theoretical compression system model. Journal of Engineering for Power, 98(2), 190-198. DOI 10.1115/1.3446138
  3. Haeckel, T.; Paul, D.; Leichtfuss, S.; Schiffer, H.-P.; Eissler, W. (2023). Determination of a numerical surge limit by means of an enhanced Greitzer compressor model. International Journal of Turbomachinery, Propulsion and Power, 8(4), 48. DOI 10.3390/ijtpp8040048